Fit-out packages, operations spares, and long-lead power and cooling. One quote, with a lead time on every line.
Send one list across all three. We quote what we can supply from stock, chase what is long-lead, and flag gaps we spot in the bill of materials.
Everything around the servers when you add racks or a hall: rack PDUs, cabinets and containment, structured cabling and fiber, optical transceivers and DAC/AOC cables, IEC cords, cable management, and liquid-cooling connections (manifolds, hoses, quick-disconnects). Delivered by phase to the site.
What a running facility buys every month: MERV filters, UPS replacement batteries, breakers, fans and power supplies, server memory and drives by exact part number, arc-flash PPE, ESD and clean-room supplies. Recurring orders shipped on your schedule.
Switchboards, panelboards, dry-type transformers, transfer switches, and busway, with a lead time on every line. Medium-voltage switchgear, large transformers, generator sets, and CDUs are quoted on request through specialty and factory-authorized channels. Power equipment →
Electrical and mechanical contractors, colocation and facility operations teams, developers, GPU cloud operators, and system integrators. On most projects, two people decide.
We quote the exact manufacturer part number you specified. Alternates come only when the approved part cannot land in time, with data sheets for your review. Nothing is substituted without written approval.
One quote across every category, a lead time on every line, one PO, and one invoice. Deliveries sequenced to the build schedule, labeled by project and phase, to any site.
A spreadsheet, a PDF, a partial markup, or an export from your project tool. Manufacturer part numbers are matched exactly.
Gaps we spot are flagged before we quote: optics short of the port count, cords that don’t match the PDU outlets, rails missing for the cabinets.
Stocked lines priced fast. Long-lead equipment confirmed with the manufacturer or partner. Alternates marked for engineering review, never swapped silently.
Shipments sequenced to the build calendar and labeled by project and phase. Data sheets, certifications, and safety data sheets bundled for your records.
Cabinets and containment, rack PDUs, optics and DAC/AOC cables, IEC cords, cable management, and cooling connections, delivered to the hosting facility before the servers land.
We look for stock of the approved breaker, pump, or battery module first. If it can’t land in time, we propose alternates with data sheets for your engineer to approve.
An expansion package across power distribution, cabinets, cabling, and cooling connections, on one PO, phased to the install plan.
Filters, UPS batteries, PPE, ESD and clean-room supplies, and spares on a recurring order, with audit dates and change-out schedules built in.
Quoted by exact manufacturer part number. Mix lines from all three lanes in one request.
Open-frame and enclosed cabinets, 12U-48U, 19" / 23", standard and seismic-rated. Tripp Lite SmartRack, APC NetShelter, Belden, Hubbell, Wright Line, Vertiv VR. Rail kits, blanking panels, rack-mount cable managers, levelers and casters. Hot- and cold-aisle containment: end-of-row doors, roof panels, aisle curtains, brush grommets, and floor grommets.
Basic, metered, monitored, switched PDUs. Raritan, Vertiv, APC, Geist, Server Technology, Eaton. C13 and C19 outlet density, single-phase and 3-phase, Zero-U and 1U/2U form factors. Replacement outlets, monitoring sensors, environmental probes. Busway tap-off units, power whips, and receptacles by manufacturer part number to match your busway and PDU inputs.
Cat 5e / 6 / 6A / 7 / 8 bulk copper and patch cords. Bulk fiber (OM3, OM4, OM5, OS2 single-mode and multi-mode). MPO and MTP cassettes, trunks, and assemblies. Patch panels, jacks, faceplates. Optical transceivers 10G to 800G (QSFP28, QSFP-DD, OSFP), DAC and active optical cables. Fiber inspection scopes, cleaning kits, optics testing consumables. Panduit, Belden, CommScope, Berk-Tek, AFL.
C13/C14, C15/C16, C19/C20 in P-lock, L6-30, L21-30. Standard lengths plus custom-cut for cabinet builds. Matched to the PDU outlets and server inlets on your BOM, so the count and the connector types line up.
Cable trays, ladder rack, vertical and horizontal managers, hook-and-loop bundles, Velcro strap kits, J-hooks, basket tray. Panduit, Hoffman, Eaton B-Line, Chatsworth. Sized to match your build standard.
Rack manifolds, cold plates, UQD and quick-disconnect couplings (Parker, Stäubli, CPC), coolant hoses, replacement pumps and sensors, filtration housings and cartridges, glycol coolants, corrosion inhibitors. 3M Novec dielectric fluids on 2-4 week lead times. Installation materials: pipe, valves, insulation, supports, leak detection.
MERV 8 through 16 panel and bag filters. HEPA grades on lead time for higher-spec rooms. Camfil, AAF, Koch, Filtration Group, Air Filter Engineering. Standard sizes plus custom-built panels. Filter housings, gasket seals, change-out PPE.
Rack and small floor UPS units. APC Smart-UPS, Eaton 9PX/9SX, Vertiv Liebert, Tripp Lite SmartOnline, CyberPower commercial. Replacement battery cabinets and cells by chemistry and runtime. Standby and online double-conversion topologies.
Molded-case and miniature circuit breakers, fuses, contactors, relays, surge protective devices, and replacement trip units, quoted by exact manufacturer part number: Square D, Eaton, Siemens, ABB, and GE. If the approved part is delayed, we propose alternates with data sheets for engineering review.
DDR4 and DDR5 RDIMM and LRDIMM. Enterprise SSDs (SATA, SAS, NVMe U.2 / U.3 / E1.S) and hard drives (SAS, SATA, nearline). Quoted by exact OEM part number for Dell, HPE, Lenovo, Cisco, and Supermicro, or by manufacturer part number (Samsung, Micron, SK hynix, Kioxia, Solidigm, Seagate, Western Digital). Drive carriers and trays, server fans, power supplies, and network adapters by OEM part number. New, factory-sealed, condition stated on every line.
NFPA 70E CAT 2, 4, plus 40 cal hood-rated assemblies. Salisbury, Oberon, Honeywell, Mechanix. Sized for crew, with documentation for audit. Voltage-rated rubber gloves (Class 0-4) with leather protectors. Insulated hand tools.
ESD-safe mats, wrist straps, gloves, smocks, anti-static packaging. Clean-room wipes, swabs, IPA solutions, particle-free gloves, clean-room garments. Recurring fills shipped to the site.
Switchboards, panelboards, dry-type transformers, automatic and manual transfer switches, safety switches and disconnects, and busway. Every line comes back with a lead time, and we track it to delivery. Power equipment →
Medium-voltage switchgear, substation and pad-mounted transformers, generator sets, CDUs, rear-door heat exchangers, and dry coolers. Quoted on request through specialty and factory-authorized channels, with the lead time on the quote. Selection and sizing stay with your engineer of record.
We don’t design data centers, sell GPU servers or complete storage arrays, or commission systems. Design, engineering, and commissioning stay with your engineer of record and the manufacturers’ authorized partners. We get them what they specify, on schedule.
No. GPU and compute servers are sold through the manufacturers’ authorized partners, which is where warranty and support come from. We supply what goes around them: optical transceivers, DAC and AOC cables, rack PDUs, cabinets and containment, IEC cords, cable management, cooling connections, and memory and drive spares by exact part number.
Yes. We look for available stock of the approved part first. If it cannot land in time, we propose alternates with data sheets for your engineer to review. Nothing is substituted without written approval, and every line on the quote carries a lead time.
No. Design, engineering, and commissioning stay with your engineer of record and the manufacturers’ authorized partners. We source and deliver what they specify, flag gaps we spot in the bill of materials, and keep lead times visible on every line.
Stocked lines are usually priced in minutes. Long-lead power and cooling equipment is quoted as manufacturers and partners confirm availability. Either way, every line comes back with a lead time.
Yes. Camfil, AAF, Koch, Filtration Group, Air Filter Engineering. Standard sizes plus custom-built bank panels on 1-3 week lead times depending on dimensions.
Yes. CAT 2, 4, plus 40 cal hood-rated assemblies. Salisbury, Oberon, Honeywell. Sized for crew with documentation packages for audit.
Yes. C13/C14, C15/C16, C19/C20 in P-lock, L6-30, L21-30. Standard lengths plus custom-cut for cabinet builds. ITT Cannon, Tripp Lite, AC Infinity, Hubbell.
Yes. Open-frame and enclosed cabinets, 12U-48U, 19" and 23" widths, standard and seismic-rated. Tripp Lite SmartRack, APC NetShelter, Belden, Hubbell, Wright Line, Vertiv VR. Rail kits, blanking panels, rack-mount cable managers. Rack PDUs (basic, metered, monitored, switched) from Raritan, Vertiv, APC, Geist, Server Technology, Eaton in C13 and C19 density, single-phase and 3-phase.
Yes. Rack and small floor UPS units across APC Smart-UPS, Eaton 9PX / 9SX, Vertiv Liebert, Tripp Lite SmartOnline, CyberPower commercial. Standby and online double-conversion topologies. Replacement battery cabinets and cells available separately by chemistry and runtime. Larger central / paralleled UPS plants route through specialty channels with longer lead times.
Yes. Bulk fiber (OM3, OM4, OM5, OS2 single-mode and multi-mode), MPO and MTP cassettes and trunk assemblies, patch panels, jacks, faceplates. Cat 5e through Cat 8 copper for top-of-rack. Optical transceivers and active optical cables, 10G to 800G. Fiber inspection scopes, cleaning kits, optics testing consumables. Panduit, Belden, CommScope, Berk-Tek, AFL.
Yes for the consumables and accessories side of the liquid-cooling stack. Coolant hoses and tubing (Parker, Eaton Aeroquip, Gates, Continental). Quick-disconnect couplings (Parker, CPC) for closed-loop reconfigurations. Coolant filtration housings and cartridges (Eaton, Pall, Donaldson, Parker side-stream). Glycol coolants, corrosion inhibitors, biocides. Standard valves (Apollo, Watts, NIBCO) for distribution and isolation.
Yes. Optical transceivers (SFP+, SFP28, QSFP28, QSFP56, QSFP-DD, OSFP; 10G to 800G), DAC and active optical cables (AOC), and breakout cables, OEM or coded-compatible for Cisco, Arista, Juniper, and NVIDIA switches, quoted by exact part number.
Yes, as spares and refresh parts by exact part number. Server memory (DDR4 and DDR5 RDIMM and LRDIMM), enterprise SSDs (SATA, SAS, NVMe U.2, U.3, E1.S), and enterprise hard drives (SAS and SATA, including nearline), quoted against the OEM part number for Dell, HPE, Lenovo, Cisco, and Supermicro servers or the manufacturer part number (Samsung, Micron, SK hynix, Kioxia, Solidigm, Seagate, Western Digital). Drive carriers and trays too. Every line states condition; we quote new, factory-sealed parts. Complete servers and storage arrays are outside our lane.
Yes, by part number. Rack and row manifolds, cold plates, UQD and quick-disconnect couplings (Parker, Stäubli, CPC), hoses and fittings, replacement pumps, sensors, strainers, and plate heat exchanger gaskets, plus installation materials: pipe, valves, insulation, supports, and leak detection. OEM-specific cold plates and CDU spares are quoted against the manufacturer part number; some route through the manufacturer with longer lead times, and we say so on the quote.
Not from stock. CDUs (Vertiv Liebert, CoolIT, Asetek, Stulz), rear-door heat exchangers (Coolcentric, Motivair, Schneider Uniflair), and dry or fluid coolers (Baltimore Aircoil, EVAPCO) are capital equipment sold through factory-authorized channels. We quote them on request through those partners, with the lead time stated on the quote. Selection and sizing stay with your engineer of record. We also supply the parts and consumables around them: manifolds, cold plates, hoses, quick-disconnect couplings, filtration cartridges, coolants, replacement pumps and sensors, valves, and installation materials.
3M Novec 7100 / 7300 / 7500 series available through specialty supplier channels with typical 2-4 week lead times. Submer SmartCoolant, Engineered Fluids ElectroCool, Castrol DC Coolant, and other OEM-specific fluids route through their direct sales and are not in our standard supplier lane today.
Stocking sizes in 2-3 business days. Custom panels 1-3 weeks. Tell us the audit date and we will sequence shipments to land before deadline.
Yes. Upload the BOM, we price across our catalog, deliver by phase to the build site. Standard for fit-out work where the BOM spans 200-2,000 lines.
Yes. We work directly with EPC and MEP firms doing critical-facility build-outs. Single PO, ship to site, schedule-locked deliveries, per project.
Yes. ESD-safe mats, wrist straps, gloves, smocks, cleaning supplies. Anti-static packaging. Clean-room wipes, swabs, IPA solutions, particle-free gloves.
Net-30 with credit review. Major operators and EPC firms typically pre-qualify within 7 days. Project-mode billing supported for milestone POs.
Paste it or attach it. We reply with pricing and a lead time on every line, with alternates clearly marked.